20-102296 - Permit FinalCity of Federal Way"
Community Development Dept.
33325 8th Ave S
Fedetal Way, WA 98003
Ph: (253) 835-2607 Fax: (253) 835-2609
Project Name: KUMAR ESTATES LOT 4
Project Address: 29808 18TH PL S
Building Sil g1,e,!-FAmi1y
Permit #:20-1024
96-00-�i
Inspection Request Line: (253) 835-3050
Parcel Number: 367440 0138
Project Description: BLUEBEAM - Construction of a 3697 square foot 2-story single family residence with a 214
square foot covered entry and 38 square foot deck. Includes plumbing and mechanical. ***9
Bedrooms; $600,000 Estimated Selling Price***
Owner
Applicant
Contractor
Lender
KUSHAL KUMAR
SCOTT BONIFIELD
K K GENERAL CONTRACTOR
OWNER IS LENDER
29808 18TH AVE S
30346 LOTH AVE S
LLC
FEDERAL WAY WA 98003
FEDERAL WAY WA 98003-4104
29801 18TH AVE S
FEDERAL WAY WA 98003
Census Category: 101 - New Single Family House
Includes:
# 1
#2
#3
44
Occupancy Class:
R-3
Construction Type:
Type V - B
Occupancy Load:
Floor Area (sq. ft.)
3,697.00
Additional Permit Information
New / Additional Sq. Feet - 1 st Floor .....................
2218
New / Additional Sq. Feet - 3rd Floor .....................
0
New / Additional Sq. Feet - Basement ....................
0
Occupancy # I - Construction Type .........................
Type V - B
New / Additional Sq. Feet - Garage ........................
0
Plumbing Work Valuation? .....................................
15000
Number of Stories ...................................................
2
Plumbing to be Included? ........................................
Yes
Will Certificate of Occupancy be Issued? ...............
Yes
Comprehensive Plan Designation ........................... SF - High -Density
Residential
Total Valuation: 453,125.68
New / Additional Sq. Feet - 2nd Floor ....................
1479
Occupancy # 1 - Area (Sq. Feet) ..............................
3697
BasicPlan?...........................................................
No
New / Additional Sq. Feet - Deck ...........................
38
Mechanical to be Included? .....................................
Yes
Mechanical Work Valuation? ..................................
10000
New / Additional Sq. Feet - Other ..........................
214
New / Additional Sq. Feet - Total ...........................
3949
Occupancy # 1 - Use ............................ .........
Residence (I or 2
family)
Zoning Designation .................................................
RS 7.2
Mechanical Fixtures
Ducting I Fans I Furnaces I
Gas Piping 1 Gas Pipe Outlets 3 Hot Water Tanks i
Plumbing Fixtures
Dishwashers I Laundry Washer Outlets 2 Lavatories 8
Showers 3 Sinks 2 Water Closets 8
Hose Bibbs 2
CONDITIONS:
FIRE REVIEWER CONDITIONS
Automatic Fire Sprinklers ARE REQUIRED per IFC 503 and/or 508
1. Install an automatic fire sprinkler system in accordance of NFPA 13D.
2. Demolition & construction shall conform to the requirements of International Fire Code chapter 14.
3. Install interconnected smoke alarms and carbon monoxide alarms.
PERMIT EXPIRES gund`hy, 7 March, 2021
Permit Issued on Tuesday, September 8, 2020
I hereby certify that the above information is correct and that the construction on the above described property
and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of
Washington and the City of Federal Way.
Owner or agent: P" Date;
zkon --1
City of Federal Way
Certificate of Occupancy
This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section
R110 of the International Residential Code is certifying that at the time of issuance, this structure was in
compliance with the various ordinances of the City regulating building construction or use. This certificate is valid
ONLY when endorsed by City staff.
Tenant Name: KUMAR ESTATES LOT 4
Address: 29808 18TH PL S
Permit # 20-102296-00-SF
Includes: #1 #2 #3 #4
Occupancy Class: R-3
Construction Type: Type V - B
Occupancy Load:
Floor Area (sq. ft.) 3,697.00
Owner Name: KUSHAL KUMAR
Owner Address: 29808 18TH AVE S
FEDERAL WAY WA 98003
)
Building Official
'O z 7
Date f
The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which
experience has shown most severely affect the health and safety of the general public. Although the City has made as complete
a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees
nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every
ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon
which it is situated. Such compliance is the responsibility of the owner and / or occupant of the premises.
CITY OF
Federal Way
THIS CARD IS TO REMAIN ON -SITE
Construction Inspection Record
INSPECTION REQUESTS: (253) 835-3050
PERMIT #: 20 102296 00 Address: 29808 18TH PL S
Project: KUSHAL KUMAR FEDERAL WAY WA 98003
Scheduled inspections maybe failed if this card is not on -site. DO NOT LOSI'i THIS CAM). inspections are listed as close to sequential order as possible
(read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if
you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card.
❑ SWM Precon Site Mtg (4400) ❑ Initial Erosion Control (4365) ❑ Footings/Setback (4110)
Approved To be done PRIOR to breaking ground Approved to place concrete
By Date By Date By Date
❑ Foundation Wall (4115) ❑ Drainage/Downspout (4040) ❑ Plumbing Groundwork (4190)
Approved to place concrete Approved to backfill Approved to cover
By Date By Date By Date
❑
Slab/Concrete Floor (4255)
❑
Underfloor Framing (4285)
❑
Floor Sheathing (4105)
Approved to place concrete
Approved to sheath floor
Approved to install flooring
By
Date
By
Date
By
Date
0
By
Shear Walls (4245)
Approved to install siding
Date
❑
By
Roof Sheathing (4220)
Approved to install roofing
Date
❑
By
Rough Plumbing (4230)
Approved
Date
El
By
Mechanical Rough -in (4165)
Approved
Date
❑
By
Gas Piping (4125)
Approved to release test
Date
t]
By
Fire/Draft Stops (4095)
Approved
Date
E] Interim Erosion Control (4370)
Approved
By Date
❑
Insulation (4150)
E°
Gypsum Wallboard Nailing (4130)
❑
Final Erosion Control (4375)
Approved to install wallboard
Approved to install mud & tape
Approved
By
Date
By
Date
By
Date
El
Final - Mechanical (4065)
❑
Final - Plumbing (4075)
❑
Final - Building (4050)
By
Approved
Date
By
Approved
Date
By
Approved'
� Date 1012�IJ
❑
Rough Electrical
Final Electrical
Right of Way
Approved
Approved
Appl oved
By
Date
By
Date
By
Date