Loading...
20-102203-SF-Water Availability-06-14-2020-V120-102203-SF-Water Availability-06-14-2020-V1 ttLakehaven WATER & SEWER DISTRICT Lakehaven Water & Sewer District - Development Engineering Section 31623 - 1st Ave S * PO Box 4249 * Federal Way, WA 98063-4249 Email: DE@Lakehaven.org * Telephone: 253-945-1581 or 253-945-1580 This certificate is intended to provide the applicant, land use agencies &/or public health departments with information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole discretion, reserves the right to delay, or deny, water service based upon capacity &/or supply limitations in Lakehaven's or Other Purveyor's system facilities. Proposed Land Use: ® Building Permit-SFR (8) ❑ Building Permit-MFR () ❑ Building Permit -Other ❑ Subdivision () ❑ Short Subdivision () ❑ Binding Site Plan ❑ Boundary Line Adjustment ❑ Other (specify/describe) Tax Parcel Number(s): 367440-0136, -0137, -0138, -0139, -0140, -0141, -0142, -0145 Site Address: 298XX - 18th Ave S Ex. Bldg. Area to Remain: N/A sf New Bldg. Area Proposed: UNKNOWN sf LWSD GIs Grid: K-06 WATER SYSTEM INFORMATION 1. ® Water service can be provided by service connection to a new 8" diameter water main that is approximately 5-15 (+/-) feet from each new lot. 2. ❑ Water service for the site will require an improvement to LWSD's water distribution system of: ❑ a. feet of " diameter water main to reach the site; and/or ❑ b. The construction of a water distribution system on the site; and/or ❑ c. A major portion of LWSD's comprehensive water system plan would need to be implemented and/or constructed; and/or ❑ d. Other (describe): 3. ® a. The existing water system is in conformance with LWSD's Comprehensive Water System Plan. ❑ b. The existing water system is not in conformance with LWSD's Comprehensive Water System Plan and an Amendment to this Plan will be required. This may cause a delay in issuance of land use approvals or permits. 4. ® a. The subject property is within the corporate limits of Lakehaven Water & Sewer District, or has been granted Boundary Review Board approval for extension of water service outside of LWSD's water service area. ❑ b. Annexation or Boundary Review Board approval will be necessary to provide service. S. Water service is subject to: ® a. Payment of connection charges (to be determined by LWSD); ® b. Proof or reservation of easement(s) as required by LWSD (new meters & fire hydrant); ® c. Other: LWSD Service Connection applications required (1/lot). Associated LWSD DE Agreement (6317014)project must be accepted by LWSD, prior to service connection activation(s). Comments/special conditions: The nearest fire hydrant is on the Property (as marked on map on the back of this page). Fire Flow at no less than 20 psi available within the water distribution system is a minimum 1 000 GPM for two (2) hours or more. This flow figure depicts the theoretical performance of the water distribution system under high demand conditions. Fire flow rates greater than this may be accommodated through water distribution system improvements, contact LWSD for additional information. 578 Pressure Zone Est. Meter Elevation(s)-GIS: High 457+/-, Low 450+/- Est. Pressure Range at Meter(s) (psi): 49-61 I hereby certify that the above water system information is true. This certification shall be valid for one (1) year from the date of signature. Name: BRIAN ASBURY Title: DEVELOPMENT ENGINEERING SUPERVISOR Signature: J%tt[an alj e-glq,.l2 d ) Kumar Estates 2-9.docx (Form Update 3/13/20) Date: 6/12/20C RECEIVED Jul 14 2020 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT Page 1 of 4 6453450000 29�'r45} Ex. i1 Hydr. r 3$74400135 r 36744U0131 29850 3$74400125 291344 3074400130 367440-D130 2D1352 3874400 5 1912 3874400137 367440 204 31174400135 Y,74 D157 2 D7 3437 440-D139 H-ew Hydr. 387440014-D op`yy`= 3674400143 3674400142 M 4400151 2SS21! . 3674400152 29S2a NOTE: Lakehaven WatE-r and Sewe District neither warrant=- nar guarantees he accuracy -Df any farilitp infnrmatinn provided. Facility lacations and Conditions arE subjectt-D fie Id verificati-Dn. Kumar Estates 2-9.docx (Form Update 3/13/20) 3OT440-D155 3OT440015D 29S 30 T440019DI 29513 36744001 S7 I 29S 15 30744001,90 19M VhterCertificate efAir aiIabiIity Geis 36T440-0136, -013T, -0138. -0139. -0140. -0142. -0143, -014 ' REC�}E 6/12; of S41 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT Page 2 of 4