20-104946-MF-Building Permit Application-12-23-2020-V141k CITY OF Federal Way PERMIT NUMBER 2 0 PERMIT APPLICATION PERMIT CENTER + 33325 81h Avenue South + Federal Way, WA 98003-6325 253-835-2607 + FAX 253-835-2609 + permitcenterna,citvoffederalway.com - 1 0 4 9 4 6- M F TARGET DATE SITE ADDRESS SUITE/UNIT # 118 S 339th Circle, Federal Way, WA 98023 A, B, C & D PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL # $ 600,000 RM2400 1 3 2 2 0 2_ 0 0 4 0 TYPE OF PERMIT IXBUILDING ❑ PLUMBING ❑ MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT Fire damage repair to 4 lex of all units. Remove & Replace interior finishes & PROJECT DESCRIPTION Detailed description of work to fixtures in all units, replace roof with PE trusses over units, reframe exterior/interio walls per plans, rebuild at -grade & upper decks & reframe wood chases be included on this permit only NAME PRIMARY PHONE Binh Nguyen & Tuy Lan Thi 206 265-2617 PROPERTY OWNER MAILING ADDRESS E-MAIL 118 S 339th Circle CITY STATE ZIP Federal Wa WA 98023 NAME NW Builder Group PHONE 253-236-8319 MAILING ADDRESS 19903 32nd St Ct E E-MAIL justin@nwbuildergroup.com CONTRACTOR CITY Lake Tapps S E A ZIP 98391 FAX 253-246-7157 WA STATE CONTRACTOR'S LICENSE # EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE # NWBUIBG838NP 08 / 17 / 21 NAME PRIMARY PHONE Jesse Binford 253-833-5557 APPLICANT MAILING ADDRESS 3605 C St NE E-MAIL jbinford@bcie.net CITY Auburn STATE WA ZIP 98002 FAX 253-833-7309 NAME Same as applicant PRIMARY PHONE PROJECT CONTACT MAILING ADDRESS E-MAIL (The individual to receive and respond to all correspondence CITY STATE ZIP FAX concerning this application) PROJECT FINANCING NAME n/a - insured loss ❑ OWNER -FINANCED When value is $5,000 or more MAILING ADDRESS, CITY, STATE, ZIP PHONE (RCW 19.27.095) I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as apart of this application. SIGNATURE: DATE PRINT NAME: Bulletin #100 —January 29, 2016 Page 1 of 2 k:AHandouts\Permit Application MECHANICAL PERMIT $ 4,800 Indicate how many of each type offixture to be installed or relocated as part of this project. Do not include existing fixtures to remain. AIR HANDLING UNITS 12 FANS GAS PIPE OUTLETS OTHER (Describe) AIR CONDITIONER 4 FIREPLACE INSERTS HOODS (commercial) BOILERS FURNACES HOT WATER TANKS (Gas) COMPRESSORS GAS LOG SETS REFRIGERATION SYST DUCTING GAS PIPING WOODSTOVES PLUMBING PERMIT Indicate how many of each type o ixture to be installed or relocated as part of this project. Do not include existing fixtures to remain. BATHTUBS (or Tub/shower combo) LAVS (Hand Sinks) 8 TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER (Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS SINKS (Kitchen/Utility) WATER HEATERS (Electric) HOSE BIBBS SUMPS WASHING MACHINES 32 TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS no Lakehaven Lakehaven 588,000 $ EXISTING/PREVIOUS USE LOT SIZE (In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? Multi -Family (4plex) 11,584 ❑ Yes EX No ❑ Yes iXNo RESIDENTIAL - NEW OR ADDITION AREA DESCRIPTION (in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE BASEMENT ............................................................................................................................... FIRST FLOOR (or Mobile Home) 1,952 1,952 ............................................................................................................................... 1111111111111111111 SECOND FLOOR 1952 1,952 ............................................................................................................................... COVERED ENTRY ............................................................................................................................... DECK ............................................................................................................................... GARAGE ❑ CARPORT ❑ ............................................................................................................................... OTHER (describe) ............................................................................................................................... Area Totals EXISTING 3,904 PROPOSED TOTAL 3,904 ............................................................................................................................... "NEW HOMES ONLY" LESTIMATED SELLING PRICE $ # OF BEDROOMS COMMERCIAL — NEW/ADDITION AREA DESCRIPTION Area in Square Feet Occupancy Group(s) Construction Type # of Stories Additional Information NEW BUILDING ADDITION COMMERCIAL — REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION Area in Square Feet Occupancy Group(s) Construction Type # of Stories Additional Information TOTAL BUILDING TENANT AREA ONLY PROJECT AREA ONLY Bulletin #100 — January 29, 2016 Page 2 of 2 kAHandoutsTertnit Application