21-101538-CO-SITE PLAN21-101538-CO-0-04-26-2021-V1 GENERAL NOTES: l . DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENT. 2. IN CASE OF DISCREPANCIES OR CONFLICTS, NOTIFY ARCHITECT OF RECORD AS SOON AS POSSIBLE. 3. FOR BIDDING PURPOSES; WHERE CONFLICTS EXIST BETWEEN DRAWING DETAILS & SPECIFICATIONS, THE MORE STRINGENT SPECIFICATION SHALL APPLY. 4. G.C. IS RESPONSIBLE FOR ALL ASPECTS OF BUILDING CONSTRUCTION DELINEATED IN THESE DRAWINGS UNLESS SPECIFICALLY NOTED OTHERWISE. 5. THE SOILS REPORT IS PROVIDED UNDER SEPARATE COVER. THE GENERAL CONTRACTOR SHALL REVIEW THE REPORT AND COMPLY WITH ALL REQUIREMENTS OF SOILS REPORT. NOTIFY THE ARCHITECT IF THERE ARE REQUIREMENTS WHICH CANNOT BE MET DUE TO SITE CONDITIONS. 6. CONTRACTOR SHALL VERIFY ALL DIMENSIONS ON DRAWINGS FOR CONFLICTS PRIOR TO CONSTRUCTION. THE CONTRACTOR WILL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 7. ANY DAMAGE BY G.C. OR SUBCONTRACTOR TO EXISTING ASPHALT PAVEMENT AND/OR EXISTING LANDSCAPING OUTSIDE OF CONSTRUCTION LIMIT LINE SHALL BE REPAIRED AT NO COST TO OWNER. 8. SIDEWALK ELEVATIONS TO BE COORDINATED WITH SITE AS -BUILT CONDITIONS. ARCHITECT TO BE NOTIFIED OF ANY DISCREPANCIES. 9. G.C. TO COORDINATE SLEEVING FOR AND PLACEMENT OF IRRIGATION LINES UNDER CONCRETE WALKS, CURBS, ETC.. WITH IRRIGATION / LANDSCAPE CONTRACTOR. SEE PLANS FOR LOCATIONS. 10. CONTRACTOR SHALL COORDINATE THE LOCATION OF THE THREE (3) ADDRESS SIGNS AS SHOWN ON THE EXTERIOR ELEVATIONS. 11. NO MATERIALS SHALL BE STORED ON PUBLIC PROPERTY UNLESS AN ENCROACHMENT PERMIT IS FIRST OBTAINED FROM THE PUBLIC WORKS DEPT.. 12. ALL DEBRIS SHALL BE REMOVED FROM THE PREMISES AND WORK AREAS SHALL BE LEFT IN A CLEAN (BROOM) CONDITION DAILY. 13. CONTRACTOR SHALL PROVIDE A LIST OF SUBCONTRACTORS TO RED ROBIN GOURMET BURGERS PRIOR TO START OF WORK. 14. CONTRACTOR SHALL COMPLY WITH ALL STATE AND LOCAL RULES AND REGULATIONS CONCERNING LICENSING WHICH THE APPLICABLE GOVERNING AUTHORITY MAY HAVE ADOPTED. 15. ALL WEATHER -EXPOSED SURFACES SHALL HAVE A WEATHER -RESISTIVE BARRIER TO PROTECT THE INTERIOR WALL COVERING. EXTERIOR OPENINGS SHALL BE FLASHED IN SUCH A MANNER AS TO MAKE THEM WATERPROOF. 16. REFER TO 6/CS1.0 FOR BY OWNER (B.O.) AND NOT IN CONTRACT (N.I.C.) ITEMS REFERRED IN THE CONSTRUCTION DOCUMENTS. FIRE SPRINKLER SYSTEM: (G.C. TO CONFIRM SYSTEM REQUIREMENTS WITH LOCAL MUNICIPALITY) 1. PROVIDE AN AUTOMATIC FIRE SPRINKLER SYSTEM. THE SYSTEM IS REQUIRED TO BE DESIGNED FOR AN ORDINARY HAZARD GROUP 1 DESIGN DENSITY. 2. THE FIRE PROTECTION CONTRACTOR SHALL SUBMIT PLANS AND CALCULATIONS SEPARATELY TO THE LOCAL FIRE DEPARTMENT FOR REVIEW AND PERMIT. 3. THE AUTOMATIC SPRINKLER SYSTEM IS REQUIRED TO BE INSTALLED AND TESTED FOR COMPLIANCE WITH NFPA STANDARD 13 2013 EDITION. STORAGE HEIGHT WILL BE RESTRICTED IN THIS BUILDING TO A MAXIMUM OF 12 FEET IN HEIGHT. 4. ALL COMMERCIAL -TYPE COOKING EQUIPMENT SHALL BE PROTECTED BY AN APPROVED AUTOMATIC FIRE EXTINGUISHING SYSTEM. FIRE ALARM SYSTEM: (G.C. TO CONFIRM SYSTEM REQUIREMENTS WITH LOCAL MUNICIPALITY) l . PROVIDE A FIRE ALARM AND DETECTION SYSTEM CONNECTED TO THE FIRE SPRINKLER SYSTEM. 2. THE FIRE ALARM SYSTEM AND DETECTION SHALL BE INSTALLED IN COMPLIANCE WITH NFPA STANDARD 72. 3. THE FIRE ALARM CONTRACTOR SHALL SUBMIT PLANS AND CALCULATIONS SEPARATELY TO THE LOCAL FIRE DEPARTMENT FOR REVIEW AND PERMIT. 4. THE FIRE ALARM SYSTEM IS REQUIRED TO BE AUDIBLE THROUGHOUT THE BUILDING. ADDITIONAL ALARM DEVICES MAY BE REQUIRED UPON TESTING OF THE SYSTEM. (ONLY REQ.-D. WHEN THERE ARE 100+ HEADS) 5. THE FIRE ALARM SYSTEM IS REQUIRED TO BE MONITORED BY AN APPROVED CENTRAL STATION. 6. LOCATE FIRE ALARM CONTROL PANEL IN THE OFFICE ROOM THE REQUIRED DUCT SMOKE DETECTORS SHALL BE TIED INTO THE BUILDING MONITORING SYSTEM. 7. FIRE / ALARM SYSTEM TO BE FURNISHED AND INSTALLED BY OWNER. ENERGY NOTES: 1. PROVIDE R-21 BATT INSULATION IN EXTERIOR WALLS. PROVIDE R-25CI ON ROOF. 2. FIXED WINDOWS SHALL BE SEALED TO LIMIT AIR INFILTRATION. 3. ALL EXTERIOR DOORS SHALL LIMIT AIR INFILTRATION AROUND THEIR PERIMETER WHEN IN A CLOSED POSITION. 4. PROVIDE SEAL AT HEAD, SILL AND JAMB OF WALL PENETRATIONS. 5. SITE -BUILT DOORS MOUNTED ON THE INSIDE OR THE OUTSIDE OF EXTERIOR WALLS SHALL HAVE A MIN.. 1" LAP AT JAMBS. 6. OPEN EXTERIOR JOINTS AROUND WINDOW AND DOOR FRAMES, BETWEEN WALLS AND FOUNDATIONS, BETWEEN WALLS AND ROOF, BETWEEN WALL PANELS AT PENETRATIONS OF UTILITIES THROUGH THE ENVELOPE, SHALL BE SEALED, CAULKED, OR WEATHER STRIPPED TO LIMIT AIR LEAKAGE. 7. PROVIDE A "CERTIFICATION OF COMPLIANCE" SIGNED BY THE OWNER, GENERAL CONTRACTOR, ARCHITECT, OR ENGINEER TO THE BUILDING DEPARTMENT STATING THAT THE WORK HAS BEEN PERFORMED AND MATERIALS INSTALLED ACCORDING TO THE PLANS AND SPECIFICATIONS AFFECTING NONRESIDENTIAL ENERGY DESIGN. CONTACT THE LOCAL BUILDING DEPARTMENT REGARDING EXACT REQUIREMENTS FOR SUBMITTAL. HEALTH DEPARTMENT NOTES: 1. ALL EQUIPMENT AND INSTALLATION TO MEET NATIONAL SANITATION FOUNDATION (NSF) STANDARDS. 2. ALL LAVATORIES OR HAND SINKS MUST HAVE A COMBO FAUCET OR PREMIX FAUCET CAPABLE OF SUPPLYING WARM WATER FOR A MIN. OF 20 SECONDS @ 110 DEGREES OR PER AHJ. 3. THE JANITORIAL SINK FAUCET MUST BE PROTECTED WITH AN APPROVED BACK FLOW PREVENTION DEVICE. 1 GENERAL NOTES n SCALE: NONE FIRE DEPARTMENT NOTES NOTES: 1. CONTRACTOR TO PROVIDE A SUFFICIENT NUMBER OF 2A1 OBC RATED FIRE EXTINGUISHERS IN ORDER THAT ALL PORTIONS OF THE BUILDING ARE WITHIN 75 FT. TRAVEL DISTANCE OF SAID EXTINGUISHER AND SO THAT AT LEAST ONE 2A1 OBC RATED FIRE EXTINGUISHER IS PROVIDED FOR EACH 3000 SQ. FT. OF FLOOR SPACE OR PORTION THEREOF. TWO TYPE K EXTINGUISHERS REQ. AT FRYERS. 2. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN TYPE "KI' FOR L KITCHEN. LOCATE EXTINGUISHERS PER LOCAL FIRE DEPARTMENT / AUTHORITY DIRECTION. 3. PROVIDE FIRE EXTINGUISHERS AS REQUIRED BY FIRE DEPT. PER FIELD INSPECTOR. 4. EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL, U.N.O. 5. ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT SPECIAL KNOWLEDGE OR EFFORT (NO DEAD BOLTS, NO SLIDING BOLTS, ETC.) i 6. AN OCCUPANT CONTENT SIGN SHALL BE POSTED IN EACH ASSEMBLY ROOM HAVING AN OCCUPANT CONTENT OF 50 OR MORE. 7. MAINTAIN MIN. 44" AISLES TO EXIT OR PUBLIC WAY. 8. PROVIDE EXIT SIGNS ABOVE EXITS WITH MIN. 3/4" X 6" LETTERS LIGHTED ON CONTRASTING BACKGROUND. 9. EXIT SIGNS MUST BE INTERNALLY ILLUMINATED. 10. PROVIDE TWO (2) SEPARATE POWER SUPPLIES FOR EXIT SIGNS CONFORMING TO CODE SECTION. 11. PROVIDE EMERGENCY EXIT LIGHTING PROVIDING AN AVERAGE VALUE OF ONE FOOT CANDLE AT FLOOR LEVEL. 12. ADDITIONAL EXIT SIGNS WILL BE PROVIDED AS/IF DIRECTED BY THE CITY INSPECTOR if 13. GENERAL CONTRACTOR RESPONSIBLE FOR SMOKE DENSITY RATING AND FLAME SPREAD RATING OF MATERIALS USED. n 14. INTERIOR WALL AND CEILING FINISHES FOR ASSEMBLY AREAS SHALL NOT EXCEED AN END POINT FLAME SPREAD RATING OF 200 OR CLASS C. 15. ANY DECORATIONS USED SHALL BE NON-COMBUSTIBLE OR FLAME PROOFED IN AN APPROVED MANNER. 16. DRAPES AND OTHER DECORATIVE MATERIALS SHALL BE FLAME RETARDANT. CERTIFICATION THEREOF SHALL BE PROVIDED. EXITS, EXIT SIGNS, FIRE ALARM STATIONS, HOSE CABINETS y AND EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED BY DECORATIVE MATERIALS. 0 17. ALL DECORATIVE MATERIALS SHALL BE MAINTAINED IN A FLAME-RETARDANT CONDITION. 18. INSULATION SHALL BE INSTALLED TO MEET FLAME SPREAD AND SMOKE DENSITY REQUIREMENTS PER LOCAL CODE. 19. PROVIDE OUTSIDE GAS SHUTOFF VALVE CONSPICUOUSLY MARKED. 20. G.C. TO PROVIDE AND POST OCCUPANT CONTENT SIGN NEAR FRONT DOOR. PER LOCAL v ORDINANCE REQUIREMENTS. 21. PROVIDE A "KNOX BOX" FOR FIRE DEPARTMENT ACCESS AND KEY ACCESS, LOCATION AS DETERMINED BY FIRE MARSHAL. v 22. EXIT SIGNAGE SHALL BE PROVIDED AND MAINTAINED FOR CORRIDORS AND AISLE WAYS LEADING TO EXITS IN ACCORDANCE WITH SECTION SIGNAGE SHALL STATE: "OBSTRUCTIONS, INCLUDING STORAGE, SHALL NOT BE PLACED IN THE REQUIRED WIDTH OF AN EXIT OR EXIT e PASSAGEWAY." 23. FIRE DEPARTMENT FINAL INSPECTION REQUIRED. SCHEDULE INSPECTIONS TWO (2) DAYS IN ADVANCE OR PER AHJ. 24. STORAGE, DISPENSING OR USE OF ANY FLAMMABLE AND COMBUSTIBLE LIQUIDS, FLAMMABLE AND COMPRESSED GASES, AND OTHER HAZARDOUS MATERIALS SHALL COMPLY WITH LOCAL FIRE CODE REGULATIONS. 25. ANY TYPE I HOOD INSTALLATION AND SHAFT CONSTRUCTION MUST COMPLY WITH THE LOCAL CODE REQUIREMENTS. COMPONENTS OF THE SHAFT ASSEMBLY MUST BE OF INCOMBUSTIBLE CONSTRUCTION. 26. FIRE BLOCKS SHALL OCCUR AT THE FOLLOWING LOCATIONS: A. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10-FOOT INTERVALS BOTH VERTICAL AND HORIZONTAL. B. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVE CEILINGS. '- C. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN AND IN BETWEEN STUDS ALONG AND IN -LINE WITH THE RUN OF STAIRS IF THE WALLS v UNDER THE STAIRS ARE UNFINISHED. D. IN OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, FIREPLACES AND SIMILAR _ OPENINGS WHICH AFFORD A PASSAGE FOR FIRE AT CEILING AND FLOOR LEVELS, WITH NON COMBUSTIBLE MATERIALS. E. AT OPENINGS BETWEEN ATTIC SPACES AND CHIMNEY CHASES FOR FACTORY -BUILT L CHIMNEYS. OWNER: ARCHITECT: RED ROBIN GOURMET BURGERS CHIPMAN DESIGN ARCHITECTURE 6312 S. FIDDLERS GREEN CIRCLE 1350 EAST TOUHY AVE. SUITE 200 NORTH FIRST FLOOR EAST GREENWOOD VILLAGE, CO 801 1 1 DES PLAINES, IL 60018 BRAD BELTER PH: 847-298-6900 DESIGN: PROJECT MANAGER HOANG H. DUONG P H : 303.886.6219 hdoung@redrobin.com CONSTRUCTION PROJECT MANAGER: JANET CHRISTOPHERSON P H : 207.239.2348 jchristopherson@redrobin.com PROPERTY DEVELOPMENT MANAGER: BRAD SMITH PH: 303.846.5446 bsmith@redrobin.com STRUCTURAL ENGINEER: JOHNSON WILBUR ADAMS, INC. 330 S. NAPERVILLE RD. SUITE 300 WHEATON, IL 60187 NATE BOSSENGA PH: 630-653-9060 MEP ENGINEER: WCW ENGINEERS, INC. 760 CREEL DRIVE WOOD DALE, IL 60191 SUNG KWON PH: 630-595-8800 2 PROJECT CONTACTS SCALE: NONE DEPARTMENT CONTACT PHONE PLANNING & ZONING - 253-835-2655 PLAN REVIEW - - BUILDING Ta m ra 253-835-2607 STRUCTURAL - - MECHANICAL - - PLUMBING - - ELECTRICAL https://www.pse.com/contactpse 888-225-5773 FIRE PREVENTION - - STREETS & HIGHWAYS _ _ STORM Theresa Thurlow, P.E. 253-835-2750 SANITARY/ SEWER Craig Hanson (pretreatment super) 253-945-1593 HEALTH DEPT. Diane Agasid 206-263-9566 5 LOCAL CONTACTS SCALE: NONE ACCESSIBILITY NOTES: 1. WALKS, HALLS, CORRIDORS, PASSAGEWAYS, AISLES OR OTHER CIRCULATION SPACES SHALL HAVE 80" MINIMUM CLEAR HEADROOM. 2. GROUND AND FLOOR SURFACES ALONG ACCESSIBLE ROUTES AND IN ACCESSIBLE ROOMS AND SPACES, INCLUDING FLOORS, WALKS, RAMPS, STAIRS, AND CURB RAMPS, SHALL BE STABLE, FIRM, AND SLIP -RESISTANT AND COMPLY WITH MAX. SLOPES PER A.D.A. 3. OBJECTS PROJECTING FROM WALLS WITH THEIR LEADING EDGES BETWEEN 271, AND 801, ABOVE THE FINISH FLOOR SHALL PROTRUDE NO MORE THAN 4" INTO WALKS, HALLS, CORRIDORS, PASSAGEWAYS, OR AISLES. OBJECTS MOUNTED AT OR BELOW 271, ABOVE FINISH FLOOR MAY PROTRUDE ANY AMOUNT. 4. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL CONSIST OF A WHITE FIGURE ON A BLUE BACKGROUND. THE BLUE SHALL BE EQUAL TO COLOR NO. 15090 IN FEDERAL STANDARD 599b. 5. IF RAMP RUN EXCEEDS 6" IN RISE, HAND RAILS SHALL BE PROVIDED. 6. WALL SURFACES ADJACENT TO HANDRAILS SHALL BE FREE OF SHARP OR ABRASIVE ELEMENTS. 7. THE CENTER OF ELECTRICAL AND COMMUNICATION SYSTEM RECEPTACLE OUTLETS SHALL NOT BE INSTALLED LESS THAN 15" A.F.F. OR WORKING PLATFORM. 8. THE CENTER OF THE GRIP OF THE OPERATING HANDLE OF CONTROLS OR SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES, OR COOLING, HEATING, AND VENTILATING EQUIPMENT SHALL NOT BE MORE THAN 48" ABOVE THE FINISH FLOOR OR WORKING PLATFORM. 9. THE CENTER OF FIRE ALARM INITIATING DEVICES (BOXES) SHALL BE LOCATED 48" A.F.F., WORKING PLATFORM, GROUND SURFACE, OR SIDEWALK. 10. IF EMERGENCY WARNING SYSTEMS ARE REQUIRED, THEY SHALL ACTIVATE A MEANS OF WARNING FOR THE HEARING IMPAIRED. 11. APPROVED NOTIFICATION APPLIANCES FOR THE HEARING IMPAIRED SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF NFPA 72. 12. STROBE SIGNALING DEVICES REQUIRED FOR THE HEARING IMPAIRED SHALL BE STATE FIRE MARSHAL APPROVED AND LISTED. RED ROBIN GOURMET BURGERS & BREWS FEDERAL WAY 31920 GATEWAY CENTER BLVD. FEDERAL WAY, WA (CONVERSION) SITE LOCATION ASS00aWN, PLLG OChelsea Court vCondominiums e P s Truman lome Care � Co. Wiry Garden "170S, S31Ith 5i 33aThs, Q 13 p HamgtOn inn B, Su,!, & East indla Grill ® H TA-W,OeW" ® 2 vSeattle/Fed'erel Way. a a * 15271 ASteak4ouseiii Te1-1 �r V� Gateway Center ` a Slwpp q me '9 10 Q a •;� IQ 37424Ga[ew4y%� p�,j� ' Centert3 S HedereL_ MCDonald's i SktwVl-0nliwY v � /� Ah 5t - S32Dth St S320th St 53201h St .l+)[¢h5 c""rI"' ~ ` Calvary Wlheran Church© ProWash© v h 9Federal Way/S 324th _ si Park $ Hide Federal Way Cllnlc... ? Mary Jane's vHouse of Glass Best Western Plus + vepaliel ararc Seatileffederel Way - 3.9*(102s) , 1' A, 3-star hIXA El El t9 NORTH 3 AREA MAP SCALE: N.T.S. OWNER FURNISHED (B.O.) AND NOT IN CONTRACT (N.I.C.) ITEMS B-O. Items shown or noted as "B.O." or "By Owner" on the drawings and/or in the specifications shall be furnished by Owner to Contractor/subcontractor for installation by Contractor/subcontractor as part of the construction contract. Contractor/subcontracto shall receive, to the extent of unloading at the job site as required, store and be responsible to the extent of carrying necessary insurance to cover items in case of theft, fire, loss, malicious damage and other miscellaneous damage. Refer to Section 01018 of the Building Specifications for a complete list of B.O. Items. N-I.0 Items shown or noted "(NIC)" on the drawings and/or in the specifications shall be furnished and installed by Owner under separate contract, except as described hereinafter. Refer to Section 01018 of the Building Specifications for a complete list of N.I.C. Items. NOTE: B.O. and N.I.C. Items are noted through out the construction documents. If a discrepancy exists the specifications shall prevail. 4 SITE LOCATION SCALE: N.T.S. BUILDING SUMMARY/CODE REVIEW DESCRIPTION CODE SECTION REQUIREMENTS APPLICABLE CODES: - - BUILDING: 2018 IBC W/ AMENDMENTS - - MECHANICAL: 2018 IMC W/ AMENDMENTS - - PLUMBING: 2018 UPC W/ AMENDMENTS - - ELECTRICAL: 2020 NEC - - ACCESSIBILITY: ICC/ANSI Al 17.1-2009 - - HEALTH: - - USE GROUP CLASSIFICATION: 303.1 A-2 BUILDING CONSTRUCTION TYPE: 602.5 VB FIRE SPRINKLERS: 903.2.1.2 EXISTING NUMBER OF STORIES - ALLOWED / ACTUAL: 504.4 1 / 1 BUILDING HEIGHT - ALLOWED / ACTUAL: TABLE 504.3 60'-0" / 24'-0" BUILDING AREA: TABLE 506.2 7,348 SQ. FT. 6 PROJECT RESPONSIBILITY MATRIX NUMBER OF EXITS - REQUIRED / ACTUAL SCALE: NONE SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SECTION ELEVATION DOOR TAG- TAG- SEE TAG- SEE SEE DOOR DWG, AS X DWG. AS SCHD. x x NOTED NOTED X O DETAIL TAG- INTERIOR/ x SEE DWG. AS NOTED XX EXTERIOR FINISH TAG- O COLUMN LINE x x RESTROOM ACCESSORIES - SEE FINISH LEGEND ELEVATION PLAN REVISION BENCHMARK KEYNOTES TAG xx Qx ELEVATION MULTIPLE WINDOW X TAG X X ELEVATION TAG TAG SEE WINDOW X X X SCHEDULE A-1 X 1022.1 2/4 CALCULATED OCCUPANT LOAD: WAITING / STANDING AREA (5 SF PER PRSN): TABLE 1004.5 19 PERSONS WAITING BENCHES (24" PER PRSN): 1004.6 288" = 16 PERSONS DINING - TABLES & CHAIRS (15 SF PER PRSN): TABLE 1004.5 613 SF = 41 PERSONS DINING - FIXED BOOTH (24" PER PRSN): 1004.6 85 PERSONS DINING - FIXED BANQUETTE (18" PER PRSN): 1004.6 50 PERSONS DINING - FIXED SEATS: 1004.6 24 PERSONS STORAGE / MECHANICAL (300 SF PER PRSN): TABLE 1004.5 2 PERSONS KITCHEN: TABLE 1004.5 8 PERSONS EMPLOYEES (MAX. PER SHIFT): TABLE 1004.5 OFFICE (100 SF PER PRSN): TABLE 1004.5 1 PERSONS BUILDING OCCUPANCY: 246 TOTAL PERSONS REQUIRED PLUMBING FIXTURES (PLUMBING OCCUPANCY LOAD: XXX) LAVORATORIES REQUIRED / PROVIDED: - 2 EA. / 3M, 3F MEN TOILETS/URINALS REQUIRED / PROVIDED: - 2 T, 1 U / 2 T, 2 U WOMEN TOILETS REQUIRED / PROVIDED: - 2/3 NOTE TO G.C: IT IS ASSUMED THAT THE G.C. SHALL PERFORM THE WORK AS ILLUSTRATED WITHIN THE PERMITTED DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN THE EVENT THAT SITE CONDITIONS PREVENT THE WORK FROM BEING COMPLETED AS ILLUSTRATED HEREIN SO THAT ANY MODIFICATIONS (IF NECESSARY) CAN BE MADE. ANY DEVIATIONS FROM THE PERMITTED DRAWINGS WILL NOT BE ACCEPTED AND THE CONTRACTOR SHALL RECONFIGURE THE WORK AT HIS OWN EXPENSE AS REQUIRED TO BE IN CONFORMANCE WITH THE PERMITTED DOCUMENTS. THE ARCHITECT WILL NOT ACCEPT, CERTIFY OR DOCUMENT WORK DONE THAT DOES NOT CONFORM WITH THE PERMITTED DOCUMENTS FOR THE PURPOSES OF OBTAINING ANY TYPE OF MUNICIPAL APPROVAL DUE TO UNAUTHORIZED REVISIONS. Electrical by separate permit 11 CURRENT DRAWING SHEET # SHEET NAME Cover sheet CS1.0 COVER SHEET RS1.0 RESPONSIBILITY SCHEDULE Architecture D1.0 DEMOLITION PLAN D1.1 DEMOLITION REFLECTED CEILING PLAN AO.1 SUSPENDED CEILING AND WATER HEATER SEISMIC DETAILS A1.0 ARCHITECTURAL SITE PLAN A2.0 DIMENSION PLAN A2.1 WINDOW & DOOR HARDWARE AND MATERIAL SCHEDULES A2.2 FLOOR FINISH PLAN A2.3 ROOF PLAN A2.4 FURNISHING PLAN A2.5 REFLECTED CEILING PLAN A2.6 DECOR PLAN AND ELEVATIONS A2.7 FABRIC PLAN & DECOR ELEVATIONS A3.0 EXTERIOR ELEVATIONS A3.1 EXTERIOR ELEVATIONS A5.0 DINING ROOM ELEVATIONS A5.3 RESTROOM & OFFICE ENLARGED PLANS & ELEVATIONS A6.1 INTERIOR SECTIONS & DETAILS K1.0 KITCHEN EQUIPMENT PLAN K1.1 KITCHEN EQUIPMENT SCHEDULES K2.0 KITCHEN EQUIPMENT IN GROUND ROUGH -IN FLOOR PLAN FS3.0 KITCHEN EQUIPMENT ELEVATIONS FS3.1 KITCHEN EQUIPMENT ELEVATIONS FS4.0 KITCHEN EQUIPMENT ELEVATIONS t__ Structural S1.0 STRUCTURAL GENERAL NOTES S1.1 FOUNDATION PLAN S1.2 ROOF FRAMING PLAN Mech., Plumb., & Elec. ME1.1 MECHANICAL, ELECTRICAL & PLUMBING ROOF PLAN H1.1 HVAC FLOOR PLAN H2.1 HVAC EQUIPMENT SCHEDULE H3.1 HVAC DETAILS H4.1 CAPTIVE AIR DRAWINGS H4.2 CAPTIVE AIR DRAWINGS H4.3 CAPTIVE AIR DRAWINGS H4.4 CAPTIVE AIR DRAWINGS H4.5 CAPTIVE AIR DRAWINGS H5.1 HVAC SPECIFICATIONS P1.1 PLUMBING FLOOR PLAN: WASTE & VENT P1.2 PLUMBING FLOOR PLAN: WATER & GAS P1.3 GENERAL PLUMBING NOTES P2.1 PLUMBING DETAILS P3.1 PLUMBING DETAILS P3.2 WATER RISER DIAGRAM, PLUMBING DETAILS P4.1 PLUMBING SPECIFICATIONS P4.2 PLUMBING SPECIFICATIONS (CONTINUED) EO.0 ELECTRICAL SCHEDULES AND GENERAL NOTES E1.1 LIGHTING PLAN E1.2 ELECTRICAL POWER PLAN E1.3 ELECTRICAL SPECIAL SYSTEMS PLAN E1.4 ELECTRICAL SITE PLAN E2.1 ELECTRICAL DETAILS E2.2 ELECTRICAL PANEL SCHEDULES & DETAILS E2.3 DIMMING SYSTEM DETAILS E3.1 ELECTRICAL SPECIFICATIONS E3.2 ELECTRICAL SPECIFICATIONS Specifications SP1.1 SPECIFICATIONS SP2.1 SPECIFICATIONS SP3.1 SPECIFICATIONS SP4.1 SPECIFICATIONS SP5.1 SPECIFICATIONS SP6.1 SPECIFICATIONS SP7.1 SPECIFICATIONS SP8.1 SPECIFICATIONS SP9.1 SPECIFICATIONS SP10.1 SPECIFICATIONS SP11.1 SPECIFICATIONS Vendors RECEIVED Apr 28 2021 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT LU m W V) w V m W > J m (Y) WCD � 7~ /0M O ` 0, LLJ �U>Q Q > Z > CO W Q 0,n V ^' J L.L Q W W 0, 0 LU M H 0 F °D o w N O U V >a0 0 ZZ_ aw0 co 2W > J c LUD �0w o � CH 0JZ 00 F- Z LU ¢ LU Lu J Z aH F_a O IL = U) Lu V In w a M w � =a vIIIIIII000 Revisions r N C) UJ 1 1 0 W w v! vJ 0. LU 0w U 0- REGISTERED A CT C OHM A. C i 4AN TATE 4F 4VA iil GTON I HEREBY CERTIFY THAT THESE PLANS HAVE BEEN PRE- PARED UNDER MY SUPERVISION AND THAT TO THE BEST OF MY KNOWLEDGE, THE SAME COMPLY WITH ALL RULES, REGULATIONS AND ORDINANCES OF FEDERAL WAY, WA RELATING TO STRUCTURES AND BUILDINGS. ARCHITECT Drawn By Checked By Scale Date AS NOTED 03-29-2021 Job No. 20-5005 e FIRE DEPARTMENT NOTES c 7 v SCALE: NONE 8 ACCESSIBILITY NOTES SCALE: NONE 9 DRAWING SYMBOL LEGEND SCALE: NONE 10 CODE REVIEW SCALE: NONE 1 1 REVISION LOG SCALE: NONE 12 INDEX OF DRAWINGS SCALE: NONE Sheet No. CS1,0